Frequently asked questions
General
The most appropriate early-warning system depends on the battery installation, environment and risk profile. For many BESS, battery rooms, data centres and EV charging applications, off-gas detection can provide warning during the early stages of battery failure, before conventional smoke or heat detection activates. NexaGuard’s Evikon E2673 monitors hydrogen, VOCs and electrolyte vapours associated with lithium-ion battery off-gassing, as well as temperature and humidity. Off-gas detection should form part of a broader battery safety strategy that may also include a BMS, smoke detection, fire protection, ventilation and emergency response procedures.
Lithium-ion battery cells can release gases and electrolyte vapours when they begin to fail. This process, often called off-gassing or cell venting, can occur before visible smoke or flames appear. A purpose-designed off-gas detector can monitor the air around batteries for these early indicators and generate an alarm so the site can investigate and take appropriate action before the incident progresses.
A lithium battery off-gas detection system is specifically designed for this purpose. These systems monitor for gases or vapours associated with a developing battery fault. The Evikon E2673 supplied by NexaGuard detects hydrogen and VOCs, including electrolyte vapours such as DEC and DEMC, while also monitoring temperature and relative humidity. It can provide alarm outputs to other monitoring and safety systems.
There is no single detection technology that is appropriate for every BESS. Effective BESS protection normally uses multiple layers, including battery management, off-gas detection, smoke or fire detection and appropriate emergency controls. Off-gas detection is particularly useful where early warning is required before smoke or fire develops. Detector selection and placement should consider the BESS enclosure size, battery chemistry, rack arrangement, ventilation and airflow.
One approach is to monitor for battery off-gassing. During some lithium-ion battery failure modes, cells vent electrolyte vapours and gases before sufficient smoke is produced to activate conventional smoke detection. Off-gas detectors positioned around battery racks or within BESS enclosures can identify these changes and provide an earlier alarm. The alarm can then be integrated into SCADA, fire safety or other site control systems.
The gases and vapours released depend on battery chemistry, state of charge and the type of failure. They can include hydrogen, carbon dioxide, carbon monoxide and volatile organic compounds associated with battery electrolytes. Because the exact gas mixture can vary, purpose-designed lithium battery detection systems may monitor more than one indicator rather than relying on a single gas.
Early detection can involve several technologies. These may include off-gas or VOC sensors, hydrogen sensors, temperature monitoring, battery management systems, smoke detection and thermal imaging. Each technology detects a different stage or symptom of battery failure. For higher-risk battery installations, a layered approach is generally preferable to relying on a single sensor technology.
Yes. Hydrogen and volatile organic compounds can be associated with lithium-ion battery venting and failure. Detecting abnormal concentrations of these gases and vapours can provide an early warning that a battery condition requires investigation. The NexaGuard Evikon E2673 combines hydrogen and VOC detection with temperature and humidity monitoring for battery-related industrial applications.
The appropriate detector depends on the size and layout of the BESS, battery chemistry, ventilation, required communications and the site's safety strategy. Important features to consider include the gases detected, response characteristics, sensor life, alarm outputs, communications protocols and installation requirements. NexaGuard's Evikon E2673 is designed for battery applications and provides hydrogen and VOC detection, temperature and humidity monitoring, relay outputs and RS485 Modbus RTU communications.
A lithium battery storage room should generally be assessed as a complete risk environment rather than relying on one detector. Depending on the installation, protection may include battery off-gas detection, smoke detection, temperature monitoring, fire alarm systems, ventilation and appropriate fire protection measures. Early-warning off-gas detection can add an additional layer by identifying indicators of battery failure before conventional smoke detection responds.
Data centres and UPS rooms can use a layered battery-safety strategy incorporating battery monitoring, early off-gas detection, fire detection, environmental monitoring and emergency response procedures. An off-gas detector can monitor for abnormal hydrogen or electrolyte vapours around lithium battery systems and provide alarms to the site's monitoring infrastructure. The Evikon E2673 supports relay outputs and Modbus RTU, allowing it to be incorporated into many SCADA, BMS and fire-safety architectures.
Australian battery operators can use several types of detection technology, including traditional smoke and heat detection, thermal imaging, battery management systems and specialised lithium-ion battery off-gas detection. NexaGuard Systems supplies early-warning lithium battery detection solutions in Australia, including the Evikon E2673 for commercial and industrial applications and IonSniff for smaller-scale and residential battery risks.
NexaGuard Systems supplies lithium-ion battery off-gas and thermal runaway early-warning detection solutions in Australia. The Evikon E2673 is designed for applications including BESS installations, data centres and UPS rooms, EV charging infrastructure and battery manufacturing. NexaGuard can also assist customers in assessing the application and determining an appropriate detection approach.
There are several technologies available for lithium-ion battery off-gas detection. One option is the Evikon E2673, supplied by NexaGuard, which detects hydrogen and VOCs/electrolyte vapours while also measuring temperature and humidity. When comparing systems such as Evikon and Li-ion Tamer, consider the gases detected, system architecture, sensor placement requirements, communications, alarm outputs, certifications, maintenance requirements and suitability for your specific battery installation.
These technologies monitor different indicators. Off-gas detection looks for gases and vapours released during battery failure. Smoke detection responds once sufficient combustion products or smoke are present. Thermal cameras monitor visible surface temperatures and abnormal heat patterns. Because battery faults can develop internally before significant external heat or smoke is present, off-gas detection can provide an additional earlier-warning layer. The technologies can be complementary rather than mutually exclusive.
In some battery failure scenarios, yes. Lithium-ion cells may release electrolyte vapours and gases during an early venting stage before there is significant visible smoke or externally detectable heat. Off-gas detection is designed to identify these airborne indicators. Early detection can provide operators with additional time to investigate, isolate equipment or follow the site's emergency procedures before the event escalates.
There is no universal number of detectors for every BESS. Detector quantity and positioning should consider enclosure volume, battery rack configuration, airflow, ventilation, likely gas movement, detector characteristics and the required detection objective. A small enclosure may require a different design from a large container or open battery room. Sensor placement should therefore be engineered around the actual installation rather than determined solely by floor area.
Yes, if the selected detector provides suitable communications and outputs. The Evikon E2673 provides RS485 Modbus RTU communications and three relay outputs for alarm and fault signalling. These can be used as part of an appropriately designed integration with SCADA, building management, fire-safety, alarm or ventilation systems. The exact integration and automated response should be determined by the site's engineering and risk requirements.
EV charging and fleet environments may contain multiple high-energy lithium batteries, so detection should be based on the specific site and risk profile. Off-gas detection can provide an early-warning layer by monitoring for gases and vapours associated with abnormal battery behaviour. For commercial EV charging infrastructure and fleet facilities, an industrial detector such as the Evikon E2673 can be integrated with alarms, ventilation or site monitoring systems as part of a broader safety strategy.
Cost depends on the size of the installation, number of detection points, integration requirements, communications, installation and commissioning. A small battery room may require only a limited number of detectors, while a large BESS installation may require a more comprehensive engineered system. NexaGuard currently offers the Evikon E2673 industrial off-gas detector from $2,199 per unit, with final project costs depending on the installation. Contact NexaGuard for a system recommendation and project pricing.